Call (888) 788-1197
Home / Unit types / ADA Accessible Porta Potty

ADA Accessible Porta Potty Rental in the Phoenix Area

An ADA accessible porta potty is a larger, ground-level unit with room for a wheelchair to turn, grab bars and a lower seat. Federal ADA standards require at least 5% of clustered portable units to be accessible, and Mesa asks events for 10%.

Get quotes: (888) 788-1197
ADA Accessible Porta Potty example photo
Photo: Emw, CC BY-SA 3.0, labels blurred. Credits

This is the unit the rules actually name. Under ADA 213.2, any cluster of single-user portables needs at least 5% accessible units, rounded up. Phoenix says ADA toilets must be available at events, Scottsdale requires at least one if portables are provided, and Mesa sets 10% of total toilet facilities.

The unit only helps if someone can reach it. Place it on a firm, level route without curbs, gravel ruts or slopes, close to the main area.

Quick facts

ADA accessibleYes. Built to be wheelchair accessible.
Site needsA wider, level pad and an accessible route to the door.
ServicingServiced like a standard unit. Keep the route clear after each service visit.

Best uses for a ada accessible porta potty

What to ask the operator

Valley tip: Construction-only toilets are exempt under ADA 203.2, but the moment the public uses them, the accessible count applies.

The rules that apply

SourceWhat it says
2010 ADA Standards 213.2 Exception 3Where single-user portable toilets are clustered, at least 5% of the units in each cluster must be accessible, rounded up. 20 units means 1 accessible unit; 21 units means 2.
2010 ADA Standards 203.2Portable toilets used only by construction personnel on a construction site are exempt from the accessibility requirements.
City of Phoenix Special Event ChecklistADA accessible portable toilets must be available, and portable toilets may not block public sidewalks. Restroom unit permits come from Maricopa County, not the city.
Scottsdale Special Event Guidebook, Restroom FacilitiesIf portables are provided, at least one must be ADA accessible. No unit within 25 feet of a neighboring business or home entrance unless that owner approves.
Mesa Special Events Handbook (rev. Jan 2026)1 restroom per 100 attendees, or 1 portable per 300 if permanent restrooms sit within 200 feet. At least 10% must be ADA accessible. Weddings and funerals are not special events.

Summaries checked against the source on 2026-11-03. Always confirm with your permitting office.

Pricing

We are building a Phoenix Price Index from operator quotes and will publish real ranges here once we have them. Until then, see how pricing works or call for a live quote.

Questions people ask

How many ADA porta potties do I need?

At least 5% of each cluster, rounded up, under federal rules. 20 units means 1, 21 means 2. Mesa events need 10%. Scottsdale needs at least one.

Are ADA units required on construction sites?

Not when only construction personnel use them, per ADA 203.2.

Compare other units

All unit types | How many do I need?

Last reviewedNovember 3, 2026. Rules are summarized from the linked government and industry sources. We re-check them before each update. See our editorial policy.
Call now (888) 788-1197Get a quote